Technical specification

Generator specifications.

Diesel generating sets, 20 to 250 kVA, 50 Hz, three phase. The figures below are the ones we can hold whichever plant fills your order. Where our suppliers differ we publish the weaker figure, not the better one.

How to read this page

Frame data is typical for the size and is confirmed unit by unit in your quotation. We publish detailed data for the three frame sizes we have hard datasheets for. Sizes between them follow the same design and are confirmed against the plant before we quote you a number, never estimated on a page and then walked back.

Range we supply

20 to 250 kVA is the band we quote from stock designs. Sets from 50 to 125 kVA are the fastest to source and the best value per unit shipped. Above 250 kVA we can quote but lead time and freight change materially, so ask before you plan around it.

Frame data

Dimensions, weights and fuel figures are taken from manufacturer datasheets for the frame size shown.

Ratings and output

Rating35 kVA100 kVA200 kVA
Standby power(kVA)35100200
Standby power(kW)28.280160
Prime power(kVA)31.990.9180
Prime power(kW)24.772.7145
Engine speed(rpm)150015001500
Rated voltage(V)400 / 230400 / 230400 / 230
Frequency(Hz)505050
Power factor0.80.80.8

Engine and fuel

Rating35 kVA100 kVA200 kVA
Cylinders4 in line4 in line6 in line
Displacement(L)3.64.67.6
Bore x stroke(mm)100 x 115105 x 135110 x 135
Compression ratio17:117:117:1
AspirationNaturalTurbocharged, intercooledTurbocharged, intercooled
CoolingLiquidLiquidLiquid
InjectionDirectDirectDirect
Fuel at 100 percent load(l/h)9.223.440.2
Fuel at 75 percent load(l/h)6.917.530.1
Fuel at 50 percent load(l/h)4.611.720.1
Starting battery12 V / 60 A24 V / 2 x 60 A24 V / 2 x 60 A

Dimensions and weight

Rating35 kVA100 kVA200 kVA
Canopied L x W x H(mm)2000 x 950 x 14402400 x 1000 x 16402800 x 1100 x 1830
Canopied dry weight(kg)99413631916
Open set L x W x H(mm)2000 x 950 x 11002400 x 1000 x 13002800 x 1100 x 1490
Open set dry weight(kg)74110881436
Fuel tank(L)120170250

Alternator and build

These hold across every set we supply, at every frame size in the range.

Type
Brushless, three phase, synchronous, self exciting
Poles
4
Connection
Three phase four wire, star
Insulation class
H
Enclosure protection
IP23
Voltage regulation
AVR, plus or minus 1 percent steady state
Total harmonic distortion
3 percent or less
Overload
110 percent for 1 hour in every 12, prime rating
Windings
Copper

Options confirmed per order

Frequency and voltage

60 Hz and 380 V, 415 V or 440 V variants are available. State the standard in your enquiry and it is confirmed in writing before the order is placed.

Control panel

Automatic control with an LCD display as standard. The panel model is named in your quotation.

ATS

Automatic transfer switch available on request. On some sets it is included and on others it is priced separately, so it is always stated as a line item on your quote rather than assumed.

Alternator upgrade

A premium alternator is available as a paid upgrade where local parts availability and resale value matter. It is quoted as a separate line, never substituted silently.

Canopy and finish

Sound attenuated steel canopy with emergency stop, control window, exhaust silencer and electrostatic powder coating. Unbranded finish as standard.

Fuel tank

Base frame tank sized as shown. Extended run tanks can be specified at order.

Sound level

We do not publish a single sound figure. Canopied sets in this range are typically specified at 75 or 80 dB(A) at 7 m depending on frame size, and the number that applies to your unit is written into your quotation and confirmed by the plant before the order is placed. Publishing one figure for the whole range would be a number we could not hold on every set, so we do not print one.

What we do not publish, and why

We do not publish certificate numbers, issuing bodies, plant names or plant locations. Full CE and ISO documentation is supplied with every shipment and the independent inspection report is issued directly to you, so you get the evidence with the goods rather than a number on a web page you cannot verify anyway.

Need a size that is not on this page?

Send the rating, the voltage and frequency standard where it is going, and whether you need prime or standby. We confirm the exact specification with the plant and come back with a written quotation.

Request a specification